Features
1. Timer with display (based on CY8C27x43family)
Features
- Single or dual set points
- 4 digits, Seven Segment Display
- Single or dual display
- LED Status Indication: Power ON, Relay ON
- Programmable resolution (decimal point)
- Up / Down timing operation
- Password protection for configuration
Specifications:
- Accuracy : ± 0.05(with external crystal) or ± 2% of Full Scale range (without crystal)
- Start Input : Level / Pulse
- Manual Reset : Front, Remote, Power Interrupt
- Auto Reset : Programmable time
- Modes : ON delay / OFF delay
: Cyclic ON first / Cyclic OFF first - Time Range : up to 9999 (hr/min/sec)
2. Timer without display (blind timer, based on CY8C24x23A, CY8C21x23 families)
Features:
- ON delay (or) OFF delay mode
- Interval mode
- Configurable time range
- LED status indicator: Power ON, Relay ON
- DIN rail / back panel mountable
Specifications:
- Accuracy : ± 0.05(with external crystal) or ± 2% of Full Scale range (without crystal)
- RESET on interruption of power
- Supply Voltage : 230V AC
- Relay outputs (up to two, SPDT/DPDT)
Description
PSoC 1 based industrial timer provides cost effective, programmable solution to meet the market requirements. The solution is available in two flavors.
- Timers with display (based on CY8C27x43 family)
- Timers without display i.e. blind timers (based on CY8C24x23A, CY8C21x23 families)
In timers with display, user keys are available to set parameters like time, mode, pass word, etc. The control inputs (Level / Pulse) start and reset the timing operations. The integrated comparator with internal voltage reference in PSoC 1 is used to detect the power down condition to store the parameters in the emulated EEPROM (Flash memory).
In blind timers, potentiometers and DIP switches are used to set the ON / OFF time, time range, unit of time and mode. The on-chip ADC is used to interface with the potentiometers. Blind timers start timing operation immediately after it is powered ON. There is no control input logic in blind timers.
The relay outputs are turned ON (or) OFF based on the timing logic. The LEDs indicate the relay status and power on status.
BLOCK DIAGRAM - Timer with Display
BLOCK DIAGRAM - Timer without Display (Blind Timer)
PSoC value
- On-chip comparator for power down detection
- On-chip ADC to read potentiometer inputs
- Configurable platform
- IP protection
Related Files