Question: 

What is the recommended series termination resistor for the output 133 MHz clock lines from the IMI9531 Spread Spectrum Clock Generator?

Answer: 

The best termination depends on the trace length and trace impedance and capacitance being driven . A nominal value would be between 22 and 33 ohm. Make sure there are not any vias in the trace within the middle 3rd of the trace.
 