You are here

Primary Supply for VDDD in CCG3 - KBA218994 | Cypress Semiconductor

Support & Community

Primary Supply for VDDD in CCG3 - KBA218994

Last Updated: March 16, 2017
Version: 
**
Question: 

Which is the primary supply for VDDD in CCG3 - VBUS or VSYS?

Answer: 

According to the current configuration of CCG3 firmware, the VSYS power switch is always ON. The VSYS supply takes higher priority when both VBUS and VSYS are present, because the VSYS switch is always ON. When VSYS goes below the minimum specified voltage of 2.7 V (for example, in a dead battery condition), then the LDO is turned on and the VDDD is supplied by VBUS. The LDO converts the VBUS input to 3.3 V. 

Figure 3. EZ-PD CCG3 Power System Block Diagram

Provide feedback on this article

Browse KB By Product