You are here

Output Impedance of CY2305 and unused outputs. | Cypress Semiconductor

Support & Community

Output Impedance of CY2305 and unused outputs.

Last Updated: December 07, 2011

What is the output impedance of CY2305? What is the recommended series termination resistor value? Should I terminate an unused output?


The output impedance for the

CY2305 is between 20-30 ohm. We recommend using a 20-30 ohm series resistor to match a 50 ohm transmission line. 


Ideally, you should terminate your unused output to equal your other outputs. For example, if your other output load is 15 pf, then you should terminate the unused output to 15 pf. But it is also okay to leave unused output float.  






Provide feedback on this article

Browse KB By Product