You are here

Error while programming CY8CLED08 | Cypress

Support & Community

Error while programming CY8CLED08

Last Updated: December 05, 2011
Question: 

When trying to program the CY8CLED08-28PVXI with PSoC programmer 3.11, the following error is thrown:
Error shown: “PSoC Device (08 0B 22 10) is not in the Database”
What is the workaround?

Answer: 

With the 3.11 programmer, in the .DAT file related to CY8CLED08 series, the ID ‘08 0B 22 10’ has been missed. In fact, similar errors would be seen, if we try to program other packages of the CY8CLED08 family as well. Please replace the existing .DAT file with the attached file in the following path:

C:\Program Files\Cypress\Programmer\3.11\Devices

This has been fixed in programmer 3.12 and higher

File TitleLanguageFile SizeLast Updated
Download Error while programming CY8CLED08English224 bytes08/12/10
Knowledge Base Tags: 