Title: Change Relocatable Code Address



Question:

Can I change the start address of my relocatable code?



Response:

Yes. The start address of relocatable code is 100 hex by default. This can be modified in PSoC Designer under the Project --> Settings... menu. The start address of relocatable code can be changed under the Linker tab.