AN6018 - IBIS5B-1300 Camera Recommendations

Last Updated: 
Feb 09, 2016
This is an Obsolete Application Note
The document AN6018 - IBIS5B-1300 Camera Recommendations has been marked as obsolete. The obsolete version of this application note is still available with the below description but may not be complete or valid any longer. If you have any questions or require support in regards to the below application note content, please click here and create a technical support case.

This application note provides recommendations to resolve column non-uniformities in both snapshot shutter and rolling shutter modes.

After extensive evaluation we found a relation between the position of the Y-read out pointer after read out and vertical column non-uniformities in the next frame visible at higher gain settings. If the Y-read out pointer is still selecting a line during the global reset of the next frame the reset of columns will be corrupted, which will be visible after integration as column non-uniformities.