User Module Datasheet: Reference Multiplexer Datasheet RefMux V 1.3 (CY8C29/27/24/22xxx, CY8C23x33, CY8CLED02/04/08/16, CY8CLED0xD, CY8CLED0xG, CY8CTST120, CY8CTMG120, CY8CTMA120, CY8CTST300, CY8CTMA300, CY8C28x45, CY8CPLC20, CY8CLED16P01, CY8C28x43)
Last Updated: 10/23/2012
|
|
|
Version: 1.3
|
Features and Overview
-
Low voltage offset path from PMux to analog output bus
-
Provides a method to route internal references (AGND, REFHI, REFLO) to an external pin
-
Provides a 4 to 1 analog mux for switch capacitor blocks such as ADCs and filters, if used with the AMux4 User Module
-
Signals from PMux through test mux may be rail-to-rail
-
Provides a method to route external analog inputs directly to the analog output bus
The RefMux User Module switches one of three internal references (AGND, REFLO, or REFHI) to the analog output bus. Additionally, the output of the Continuous Time (CT) block PMux multiplexer can be selected. The RefMux User Module makes use of the TestMux in a CT block. These signals may be routed to a switch capacitor block on the bottom analog row or buffered and routed to an external pin. If used in conjunction with the AMux4 User Module, they form a four input analog multiplexer to route signals from one of four pins to the analog output bus.
|
这些文档仅供参考。赛普拉斯、赛普拉斯管理层、雇员及分销商对翻译错误不承担任何责任。当您在设计开发过程中使用这些文档时,我们强烈建议您参照英文版本。
これらの文献はあくまでもご参考のためのみに日本語翻訳されています。誤訳によるトラブルが発生した場合、Cypress Semiconductor Corp. 全ての子会社、関連会社、役員、従業員、販売代理店は一切の責任を負いかねます。
最新の英語版オリジナル文献を必ずご参照いただくことをお勧め致します。
Spec No: 001-13584;
Sunset Owner: YURI;
Secondary Owner: SNV;
Sunset Date: 10/18/11
|
|