Question: How should I configure the PSoC 4200 system clock to get a SARADC sample rate of 1 MSPS?

Answer: To get a sample rate of 1 MSPS at 12-bit resolution, PSoC 4200 SARADC must work at 18 MHz. The SARADC clock has a special requirement; it can only use the integral frequency divider, because the fractional frequency divider is not suitable.

Thus, to get 1-MSPS sample rate, you must set the internal main oscillator (IMO) frequency at 36 MHz. Open the Clocks tab in cydwr and click Edit Clock to set the IMO at 36 MHz, as shown in the following figure.

Figure 1. IMO Frequency Setup


Related Categories: PSoC 4200, PSoC® 4, PSoC 4100