Recommended Reflow for Cypress Parts Information

Last Updated: 04/20/2012

What is Cypress’s Parts Recommended Reflow?

Please see below Cypress Reflow Profile. Cypress’s Reflow Profile is compliant with Jedec J-STD-020D.1. You may also download this file by following the link http://www.cypress.com/?rID=51561

Example on how to get the Peak package body temperature is shown below.

Reflow Profiles (per Jedec J-STD-020D.1)

 

Profile Feature

Sn-Pb Eutectic Assembly

Pb-Free Assembly

 

 

 

Preheat/Soak

 

 

Temperature Min (Tsmin)

100 °C

150 °C

Temperature Max (Tsmax)

150 °C

200 °C

Time (ts) from (Tsmin to Tsmax)

60-120 seconds

60-120 seconds

Ramp-up rate (TL to Tp)

3 °C/second max.

3 °C/second max.

Liquidous temperature (TL)

183 °C

217 °C

Time (tL) maintained above TL

60-150 seconds

60-150 seconds

Peak package body temperature (Tp)

For users Tp must not exceed the Classification temp in Table 2A. For suppliers Tp must equal or exceed the Classification temp in Table 2A

For users Tp must not exceed the Classification temp in Table 2B. For suppliers Tp must equal or exceed the Classification temp in Table 2B

Time (tp)* within 5 °C of the specified classification temperature (Tc), see Table 2a & 2B

20* seconds

30* seconds

Figure 5-1. J-STD-020D.1

 

 

Ramp-down rate (Tp to TL)

6 °C/second max.

6 °C/second max.

Time 25 °C to peak temperature

6 minutes max.

8 minutes max.

* Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and a user maximum

.

Table 2A
SnPb Eutectic Process - Classification Temperatures (Tc)

 

Package Thickness

          Volume  mm3

<350

               Volume mm3

>=350

<2.5 mm

235 °C

220 °C

>=2.5 mm

220 °C

220 °C

 

Table 2B
Pb-Free Process -Classification Temperatures (Tc)

 

Package Thickness

     Volume mm3

<350

       Volume mm3

350 - 2000

      Volume mm3

             >2000

<1.6 mm

260 °C

260 °C

 260 °C

1.6 mm - 2.5 mm

260 °C

250 °C

245 °C

>2.5 mm

250 °C

245 °C

245 °C

Note:

  1. Peak Temperature tolerance is +5/-0 °C of Classification Temp (Tc).
  2. All temperatures refer to topside of the package, measured on the package body surface.
  3. Package volume excludes external terminals (e.g., balls, bumps, lands, leads) and/or nonintegral heat sinks.

 For example:
To be able to get the reflow profile of a part, we need to know first the Package dimension or volume. 

MPN: CY7C65620-56LTXC
Package: QFN56, Pb-Free Part
Package Dimension: 8x8x1.0mm
Package Volume: 64mm3
Package Thickness: 1.0mm

You can get package dimension on the datasheet’s Package Diagram.


Since the part is a Pb Free Part, Table 2B should be used. Based on this table, is the package volume is <350 mm3 and the package thickness is <1.6mm, Peak Temperature = 260 °C

If the part number is SnPb Part, Table 2a is applicable.


Related Categories: Clocks & Buffers, USB Controllers, Lighting & Power Control, Touch Sensing, Interface, Wireless/RF, Programmable System-on-Chip, Memory




Provide feedback on this item to help us improve:

How likely are you to recommend this article to a friend or colleague?

Not at all likely
0
1
2
3
4
5
6
7
8
9
10
Extremely likely

Was this item helpful?
Yes
No
Maybe


Additional comments:

Email:

Sunset Owner: JARG; Secondary Owner: SHBG; Sunset Date: 10/20/12