Where do I need auto reset function while using CY8CMBR2016?

The auto reset function is used to prevent false triggers from stuck sensors – for example, if the sensor is turned ON due to the presence of some object on it or some voltage spikes in the system, auto reset will disable the sensor till the object is removed or helps recover the baseline from the spike impact. For more details on timings refer to the datasheet.