Cypress Perform

Home > Support & Community
support.cypress.com     Bookmark and Share
Support & Community

Knowledge Base Article



RSSI register count accuracy

Last Updated: 12/29/2011

What kind of accuracy can be expected on the RSSI register count value?

RSSI values from the datasheet:

  • Typical Receiver Sensitivity of -90 dBm
  • Typical RSSI value for PWRin > -40 dBm is 28 - 31
  • Typical RSSI value for PWRin < -95 dBm is 0 -10

 

Our in-house testing has revealed roughly +/-7.5dBm part variance. RSSI register count vs. input power level is relatively linear over a given power level range.

General note: With a single reading, the RSSI value it is meant to be used for a crude relative signal level measurements between channels and to decide if a signal or interferer is near the noise floor or is plenty strong. Averaging several samples on a channel improves the relative accuracy significantly especially for signals near the noise floor where signal-plus-noise will cause more uncertainty in the RSSI value. The absolute accuracy of the RSSI varies from part to part but is stable over the entire temperature range (+/-1 count) and supply voltage range (+/- 0.5 count). Absolute accuracy would require a careful calibration step in a well controlled final test environment.

 

 

 

Related Categories: RF Transceivers


Provide feedback on this article

Did this article help you solve your problem?

Yes

No

Maybe

Additional comments:

To protect your privacy, do not include contact information in your feedback.

Sunset Owner: KXP; Secondary Owner: VWA; Sunset Date: 06/15/20
Spec No: None; Sunset Owner: KXP; Secondary Owner: VWA; Sunset Date: 06/15/20