|
Title
|
Customer Rating
|
Updated
|
"Old Style Function Definition" Warning in PSoC® Designer™ 5.0, 5.1, and 5.2 – KBA 83779
Question: When I compile a project using the new version of PSoC Designer, I get an “Old Style Function Definition” warning. I can build this project using earlier versions of PSoC Designer without receiving any warnings. What happened?
|
(4/5) by 3
users
|
04/04/13 |
ActiveX Controls Error in Windows Internet Explorer - KBA84416
Question: How do I resolve a Windows Internet Explorer error that says, "One or more ActiveX controls could not be displayed…"in chip view of PSoC Designer? The pop up window is shown below.
|
Not yet rated
|
03/19/13 |
Using a PRS Generator as a PWM - KBA83077
Question: How do I use a Pseudo Random Sequence (PRS) generator as a Pulse Width Modulator (PWM) in PSoC® Designer?
|
Not yet rated
|
03/19/13 |
Project Archive in PSoC® Designer™ 5.3 - KBA85754
Question: Why am I unable to open projects that were archived using PSoC® Designer™ 5.3 with the 'Minimal' option? The following message appears in the 'Status Bar': "Some of files supporting this project have not been installed."
|
Not yet rated
|
03/14/13 |
Missing Watchdog Enable Parameter in CY8C29xxx Devices - KBA85221
Question: I created a new project with one of the CY8C29xxx family devices in PSoC Designer™ 5.3. However, I cannot find the Watchdog Enable parameter in the Global Resources Window. Is there a workaround for this?
|
Not yet rated
|
01/08/13 |
Using CSD2X UM with CY8C22X45/CY8C21X45 - KBA84272
Question: When I create a new project with the CY8C22x45 or CY8C21x45 family of devices and place the CSD2X User Module (UM) version 1.0, the configuration wizard is empty. What is the workaround for this?
|
Not yet rated
|
01/07/13 |
[PSoC Designer 4.4 with Windows 7] - KBA83432
Question: Can PSoC designer 4.4 be used with Windows 7?
|
Not yet rated
|
12/26/12 |
Warning: Machine Instructions Inside .LITERAL/.ENDLITERAL Labels - KBA83511
Question: What does the warning, “Probable ERROR! Machine instructions inside .LITERAL/.ENDLITERAL will cause problems with Code Compression optimization”, mean when building a PSoC Designer project?
|
Not yet rated
|
10/18/12 |
Flash_Program_Temperature_deg_C - Parameter of the (non-CY8C20XX6A) BootLdrI2C User Module Versions 2.00-2.20 is Broken - KBA82148
Question: "Flash_Program_Temperature_deg_C" user module parameter value is ignored in the (non-CY8C20XX6A) BootLdrI2C UM versions 2.00-2.20, and is never used if the application does not call the BL_SetTemp API function. The actual temperature value that is used in the programming algorithms is always zero degrees, Celsius. What is the problem and how do I make this working?
|
Not yet rated
|
10/04/12 |
Fixing Compilation Errors While Updating UMs in PSoC® Designer™ 5.1, SP3 - KBA82259
Question: How to fix the compilation errors due to EzI2C User Module been updated?
|
Not yet rated
|
09/27/12 |
Development Environment Needed to Configure PROC-UI - KBA82018
Question: What development environment do I need to configure PRoC-UI?
|
Not yet rated
|
09/26/12 |
SETTING THE SLIDER RESOLUTION PARAMETER FOR CYONS FAMILY - KBA#82146
Question: How to set the slider resolution parameter for a CSA User Module in devices belonging to CYONS family?
|
Not yet rated
|
09/12/12 |